Case: 120666
Sending a 0 to clear a label format is not working properly. Testing: Sent and event to set the label type to 127 (PLU 9100). I then sent and event with a label type 0. The scale read and the label type for the PLU was null (odd being it should assign the scale label default). I then cleared the "0" from the PLU and sent another event. The result was the same as above. The iscale FW is at 6.4.5.72. The scale default label is set at 120. The Iscale should read the 0 or Null and allow for the scale default to load, however, the 0 looks to be passed as a value. So what we found is the scale holds a 0 and it and it is recognized as a value. If you then send a Null the 0 will stick. The only way to fix it is to delete and resend the record (same as before). (see attached for scale images)